Описание оборудования | |
---|---|
Single head system | |
General specifications | |
Measurement range | object thickness (d) : 0 ... 30 mm |
Dead band | 0 ... 15 mm |
Reference distance | 50 ... 60 mm |
Standard target plate | 10 mm x 10 mm |
Transducer frequency | approx. 850 kHz |
Response delay | approx. 12 ms |
Indicators/operating means | |
LED yellow | solid yellow: object in the evaluation range yellow, flashing: program function, object detected |
LED red | solid red: Error red, flashing: program function, object not detected |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC , ripple10%SS |
No-load supply current | ? 30 mA |
Input | |
Input type | 1 funtion input 0-level: -UBor unwired 1-level: +4 V ... +UB input impedance: > 4.7 k? |
Output | |
Output type | 1 analog output 4 ... 20 mA |
Resolution | 0.17 mm |
Deviation of the characteristic curve | ± 1 % of full-scale value |
Repeat accuracy | ± 0.5 % of full-scale value |
Load impedance | 0 ... 300 Ohm |
Approvals and certificates | |
UL approval | cULus Listed, Class 2 Power Source |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
Connection type | Connector M12 x 1 , 4-pin |
Degree of protection | IP67 |
Material | |
Mass | 25 g |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |